T-SEP Assembly for 24" Ladder Tray

Hardware Mounting Hole Access Diameter 3/8 (.375) # of Mounted Hardware Access Holes Hole Location Tube Access Area
Hardware Used 1/4" (.250) 3 (2) @ 3/8" (.375) C/L Typ.
(1) @ 11 7/16" (11.438) C/L Typ.
22 1/2" (22.500)
Tolerance 1/8" (.125) 4 (2) @ 3/8" (.375) C/L Typ.
(2) @ 7 5/8" (7.625) C/L Typ.
22 1/8" (22.125)
  5 (2) @ 3/8" (.375) C/L Typ.
(3) @ 5 13/16" (5.125) C/L Typ.
21 3/4" (21.750)
  6 (2) @ 3/8" (.375) C/L Typ.
(4)- Specify
21 3/8" (21.375)
  7 (2) @ 3/8" (.375) ea end C/L Typ.
(5)- Specify
21" (21.000)
  8 (2) @ 3/8" (.375) ea end C/L Typ.
(6)- Specify
20 5/8" (20.625)
A B C  
Tube Diameter Height Spacer Tine C/L Typ. 3 hole config 4 hole config 5 hole config 6 hole config 7 hole config 8 hole config
1/4" 1 1/2" .375" 60 59 58 57 56 54
3/8" 1 5/8" .500" 45 44 43 42 42 41
1/2" 1 3/4" .625" 36 35 34 34 33 33
3/4" 2" .875" 25 25 24 24 24 23
1" 2 1/4" 1.250" 18 17 17 17 16 16
24 inch Ladder Tray - TSEP Assembly
Notes
  1. SS316 Pneumatic Tubing Spacers: 1/4" TS-250M, 3/8 TS-375M, 1/2 TS-500M, 3/4 TS-750M, and 1" TS-100M also available with epoxy powder coated finish to Mil Spec # MIL-C-24712
  2. I-ROD: 1" half round is a UV-Stable, high impact thermoplastic Mfg. Deepwater Corrosion.
  3. Flat Bar to be 1" wide x 1/4" thick, stainless steel grade 316 or aluminum 6061-T6. Other thickness available upon request.
  4. Bar shims (1/8" thick x 1" wide) or flat washers are used to raise top flat bar retainer to level when tube size varies.
  5. When two T-SEP Assemblies rest in tandem, there exists a 1 1/8" (1.125) inch space where the assemblies meet. 1 1/8" (1.125) must be deducted from overall tube access area for each occurrence.
The T-SEP Assembly is a trademark of Production Fastening Systems, L.L.C